Sample and hold (Old block)
Each time an input event is received block copy its input on the
output and hold it until input event. For periodic Sample and hold,
event input must be generated by a Clock.
- always active: no
- direct-feedthrough: yes
- zero-crossing: no
- mode: no
- regular inputs:
- port 1 : size [-1,1] / type 1
- regular outputs:
- port 1 : size [-1,1] / type 1
- number/sizes of activation inputs: 1
- number/sizes of activation outputs: 0
- continuous-time state: no
- discrete-time state: no
- object discrete-time state: no
- name of computational function: samphold
- SCI/macros/scicos_blocks/Linear/SAMPLEHOLD_f.sci [view code]
Ramine Nikoukhah INRIA